Sign In | Join Free | My tjskl.org.cn
China Sinuo Testing Equipment Co. , Limited logo
Sinuo Testing Equipment Co. , Limited
Sinuo Testing Equipment Co., Limited
Verified Supplier

7 Years

Home > Vehicle Testing Equipment >

Clause 10.2 “A” “B” Gauge For Checking Shutters 20N 1N Rigid Steel Wires

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Clause 10.2 “A” “B” Gauge For Checking Shutters 20N 1N Rigid Steel Wires

Brand Name : Sinuo

Model Number : SN2110-5 & SN2110-6

Certification : Calibration Certificate(cost additional )

Place of Origin : China

MOQ : 1 Set

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 10 Sets / Month

Delivery Time : 30 days

Packaging Details : Standard Exporting Plywood Case

Standard Applied : IEC 62196-1 2020

Clause Applied : clause 10.2, fig. 9 & fig. 10

Gauge A Force : 20N

Gauge B Force : 1N

Gauge A diameter : Φ3mm

Gauge B diameter : Φ1mm

Contact Now

IEC 62196-1 Gauge“A”Guage“B”for Checking Shutters 20N 1N Test Probes

Product information:

These two test gauges separately confirm to the IEC 62196-1Ed.4CDV 2020 clause 10.2, figure 9 and figure 10. The SN2211-5 test probe with 20N force and the SN2211-6 test probe with 1N force.

Technical parameters:

1. Gauge "A" with force of 20N SN2211-5

Rigid steel wire part: Φ3+0.03 0×1+0.015 0×80±0.5; end rounded: R0.2±0.05, with 20N force.

2. Gauge "B" with force of 1N SN2211-6:

Rigid steel wire part: Φ1+0.015 0×80±0.5; end rounded: R0.05, with 1N force.

No.: Item Specification
1 Gauge “A” with force of 20N SN2211-5 Rigid steel wire part: Φ3+0.03 0×1+0.015 0×80±0.5; end rounded: R0.2±0.05, with 20N force.
2 Gauge “B” with force of 1N SN2211-6 Rigid steel wire part: Φ1+0.015 0×80±0.5; end rounded: R0.05, with 1N force.

Test procedures (Excerpt from IEC 62196-1Ed.4CDV 2020 clause 10.2):

An electrical indicator with a voltage between 40 V and 50 V included is used to show contact with the relevant part.
Compliance is checked by inspection and for socket-outlets with a plug completely withdrawn by applying the above gauges as follows.
The gauge according to Figure 9 is applied to the entry holes corresponding to the live contacts and to any other opening of the engagement surface with a force of 20 N.
The gauge is applied to the shutters in the most unfavourable position, successively in three directions, to the same place for approximately 5 s in each of the three directions.
During each application the gauge shall not be rotated, and it shall be applied in such a way that the 20 N force is maintained. When moving the gauge from one direction to the next, no force is applied but the gauge shall not be withdrawn.
A steel gauge, according to Figure 10, is then applied with a force of 1 N and in three directions, for approximately 5 s in each direction, with independent movements, withdrawing the gauge after each movement.
For socket-outlets and vehicle inlet with enclosures or bodies of thermoplastic material, the test is made at an ambient temperature of (35 ± 2) °C, both the socket-outlets and the gauge being at this temperature.

Work Together with Sinuo Electrical Indicator


Product Tags:

Clause 10.2 A Gauge

      

IEC 62196-1 B Gauge

      
Quality Clause 10.2 “A” “B” Gauge For Checking Shutters 20N 1N Rigid Steel Wires for sale

Clause 10.2 “A” “B” Gauge For Checking Shutters 20N 1N Rigid Steel Wires Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)